Congregate residences as defined in chapter 2 of the california building code with 3 or more sleeping units.
California building code interior doors.
Where the door opens into the stairway of a smokeproof enclosure the landing need not have a length of 5 feet.
The astragal shall be a minimum of two 2 inches wide and extend a minimum of one 1 inch beyond the edge of the door to which it is attached.
As part of the interagency support division oversees development adoption approval publication and implementation of california s building codes.
Further information california building standards commission california state fire marshal california energy commission division of the state architect 2019 residential compliance manual.
Glass in glazed curtain walls glazed storefronts and glazed partitions shall meet the seismic requirements of asce 7 section 13 5 9.
Los angeles building code 11a housing accessibility 1132a doors 1132a 2 interior doors and secondary exterior doors jump to full code chapter except as allowed by section 1109a 2 interior doors intended for user passage and secondary exterior doors shall comply with this section.
All entrances and exterior and interior exit doors regardless of the occupant load shall be made accessible to persons with disabilities.
2019 california building standards code title 24 california code of regulations.
Where a door opens over a landing the landing shall be at least as wide as the door and at least 5 feet long.
Door hardware operable with a single effort without requiring ability to grasp hardware.
The door cannot open directly onto a room used for sleeping purposes bedroom and must be one of the following types.
The astragal shall be attached to the outside of the active door by means of welding or with non removable bolts spaced apart on not more than ten 10 inch centers.
Title 24 part 2 section 2 3303 i 1 and i 2 exception.
Dwellings with 3 or more efficiency units as defined in chapter 2 of this code or section 17958 1 of the california health and safety code.
The 2019 california building standards code was published on july 1 2019 and took effect on january 1 2020.
Glass sloped 15 degrees 0 26 rad or less from vertical in windows curtain and window walls doors and other exterior applications shall be designed to resist the wind loads due to ultimate design wind speed v ult in section 1609 for components and cladding.
Section r311 2 states the width of the clear opening of the required egress door must be at least 32 inches from the face of the door to the door stop at the jamb or the opening and the height of the opening must be a minimum of 78 inches from the door stop at the head of the opening to the top of the threshold.